logo
Rumah > Produk > 3051 pemancar >
3051SFA O₂ Flow Meter – High-Accuracy Differential Pressure Gas Measurement Solution

3051SFA O₂ Flow Meter – High-Accuracy Differential Pressure Gas Measurement Solution

3051SFA O2 flow meter

high-accuracy differential pressure transmitter

gas measurement flow meter

Tempat asal:

Singapura

Nama merek:

rosemount

Nomor model:

3051SFA

Hubungi Kami
Minta Kutipan
Rincian produk
Stabilitas:
± 0,2% URL/tahun
Keluaran Sinyal:
4-20mA 2 kabel
Perlindungan Masuknya:
IP66, IP67, NEMA 4X
Aluminium Bahan Shell:
Baja tahan karat
Jenis Produk:
Pemancar
Sertifikasi:
ATEX, FM, CSA, IECEx, INMETRO, NEPSI, KOSHA, GOST-R
Gaya pemasangan:
DIN Rail atau Pipe Mount
Menampilkan:
LCD, 5 digit, 7-segmen
Suhu Sekitar:
-40 hingga 185 ° F (-40 hingga 85 ° C)
Jenis pengukuran:
Tekanan diferensial
Keluaran:
4-20 Ma, Hart, Foundation Fieldbus
Sinyal keluaran:
4 ~ 20mA mengadopsi protokol hart
Menjangkau:
-25 sampai 25 inH2O / 0,5 inH2O
Nilai akurasi:
≥ 0,05%
Suhu proses:
-40 hingga 185 ° F (-40 hingga 85 ° C)
Menyoroti:

3051SFA O2 flow meter

,

high-accuracy differential pressure transmitter

,

gas measurement flow meter

Syarat Pembayaran & Pengiriman
Kuantitas min Order
1
Harga
dapat dinegosiasikan
Kemasan rincian
karton
Waktu pengiriman
5-7 hari kerja
Syarat-syarat pembayaran
L/C,T/T
Deskripsi Produk

3051SFA O₂ Flow Meter – High-Accuracy Differential Pressure Gas Measurement Solution

The Rosemount 3051SFA O₂ Flow Meter is a high-performance differential-pressure flow meter engineered for precise oxygen gas measurement in industrial applications. Built on the trusted Rosemount 3051S platform, the 3051SFA integrates advanced sensor technology with a compact, all-in-one flow assembly, delivering superior accuracy, reliability, and installation efficiency.


3051SFA O₂ Flow Meter – High-Accuracy Differential Pressure Gas Measurement Solution 0


Feature / Model Rosemount 3051SFA Yokogawa DPharp EJX/EJA Micro Motion F-Series Siemens SITRANS FP Honeywell SmartLine STD700
Measurement Principle Differential Pressure + Annubar Digital Resonant Sensor (DPharp) Coriolis Mass Flow (not DP) Differential Pressure Differential Pressure
Accuracy ±0.05% of span ±0.04% of span (optional) ±0.5% for gas mass flow ±0.075% of span (typical) ±0.05% of span (standard)
Rangeability Up to 200:1 Up to 100:1 Up to 100:1 Up to 100:1 Up to 100:1
Sensor Type SuperModule™ DP Sensor Dual Resonant Silicon (DRS) Coriolis Tube Sensor Piezo-resistive DP Sensor Piezoresistive Sensor
Gas Compatibility Suitable for O₂, air, steam Suitable for O₂, air, steam Suitable for O₂, air, steam Suitable for O₂, air, steam Suitable for O₂, air, steam
Communication Protocols HART, WirelessHART, FF HART, FOUNDATION Fieldbus HART, Profibus, FF, Wireless HART, Profibus, Modbus HART, FOUNDATION Fieldbus
Certifications SIL2/3, ATEX, IECEx SIL2/3, ATEX, IECEx UL, CSA, ATEX, IECEx ATEX, IECEx, SIL SIL2/3, ATEX, IECEx
Installation Type Inline or Annubar insertion Inline or manifold mount Inline (Coriolis tube) Inline or orifice plate Inline or manifold mount
Best Use Case for O₂ High-accuracy industrial gas flow Stable long-term O₂ monitoring Mass flow and density in mixed gases General-purpose O₂ flow in pipelines Integrated control and diagnostics for O₂


Application Overview: Rosemount 3051SFA O₂ Flow Meter

Typical Applications

  1. Industrial Oxygen Supply Systems
    Accurate flow monitoring for oxygen distribution in manufacturing and processing plants.
  2. Chemical and Petrochemical Processes
    Ensures precise dosing and oxygen control in reaction chambers and oxidation units.
  3. Pharmaceutical and Biotech Facilities
    Supports cleanroom-grade oxygen flow control for sterile environments and gas blending.
  4. Energy and Power Generation
    Used in combustion optimization and emissions control, where oxygen flow is a key variable.
  5. Semiconductor and Electronics Manufacturing
    Enables controlled oxygen delivery for etching, oxidation, and deposition processes.
  6. Water and Wastewater Treatment
    Monitors oxygen injection in aeration systems for biological treatment efficiency.

Frequently Asked Questions (FAQ)

Q1: What type of gas can the 3051SFA measure?
A: The Rosemount 3051SFA is designed for differential pressure measurement and can accurately measure oxygen (O₂), air, steam, and other clean gases when paired with compatible primary elements like Annubar or orifice plates.

Q2: Is the 3051SFA suitable for medical oxygen applications?
A: While technically capable, the 3051SFA is optimized for industrial-grade oxygen flow. For medical or ultra-high purity applications, consult Emerson for specialized solutions.

Q3: What is the accuracy of the 3051SFA for gas flow?
A: The standard accuracy is ±0.05% of span, with enhanced performance available depending on configuration and installation.

Q4: What communication protocols are supported?
A: The 3051SFA supports HART, WirelessHART, and FOUNDATION Fieldbus for seamless integration into control systems.

Q5: Can the 3051SFA be used in hazardous environments?
A: Yes. It is certified for use in hazardous areas with approvals including ATEX, IECEx, and SIL2/3 depending on model and configuration.

Q6: What primary elements are compatible with the 3051SFA?
A: It integrates with Rosemount Annubar, orifice plates, and other differential pressure flow elements for flexible deployment.

Q7: Is the device easy to install and maintain?
A: Yes. The integrated flow assembly simplifies installation, and smart diagnostics reduce maintenance time and effort.

Q8: Does it support remote monitoring?
A: With WirelessHART or FOUNDATION Fieldbus, remote diagnostics and monitoring are fully supported.

Kirim pertanyaan Anda langsung ke kami